MITSUBISHI FX1N-40MT-D datasheet PDF

Brand: MITSUBISHI
Product model: FX1N-40MT-D
Name: PLC
Sort: PDF datasheet
File language: English
File size: 50.49MB
Protocol: SLMP, TCP/IP, UDP.
Communication mode: full duplex / half duplex.
At the same time can open a few: 4 connection.
Weight: 0.3kg.
Connect PLC FX3U/FX3UC to Ethernet.
Support fixed buffer storage, communication connection MELSOFT, through the MC communication protocol, e-mail messages.
When connected to the MELSOFT, through the Works2 PLC can achieve the remote maintenance of GX program FX1N-40MT-D PDF FX1N-40MT-D
Connecting FX3UC, FX3GC requires FX2NC-CNV-IF or FX3UC-IPS-5V. Power: 220kw.
Voltage: 400V.
The power factor of the input power factor is up to 0.99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode.
Equipped with standard power retrogradation function. Power: 1 FX1N-40MT-D PDF. 5kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table FX1N-40MT-D PDF.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor.
The installation of thermal relay, to avoid overheating and burn the braking resistor. MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 1.5kw.
SLD converter rated current: 10.5A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with tthe FR-A700 series, to reduce the volume of equipment) FX1N-40MT-D datasheet.
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network FX1N-40MT-D datasheet.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps.
Related products
MITSUBISHI
Expansion board
FX1N-8AV-BD
MITSUBISHI Expansion board FX1N-8AV-BD
8 point analog potentiometer function expansi
MITSUBISHI
PLC
FX1N-24MT-D
MITSUBISHI PLC FX1N-24MT-D
Max input / output points: 24 points. Power s
MITSUBISHI
Memory card
FX1N-EEPROM-8L
MITSUBISHI Memory card FX1N-EEPROM-8L
Memory format: EEPROM. Numer of steps: up to
MITSUBISHI
PLC
FX1N-40MR-ES/UL
MITSUBISHI PLC FX1N-40MR-ES/UL
Max input / output points: 40 points. Supply