Max input / output points: 64 points.
Supply voltage: 100 - 240VAC.
Input points: 32 points.
Output points: 32 points.
Output type: Transistor (source).
Power consumption: 60VA.
Weight (kg):1.0.
Size (WxHxD) mm:220x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter FX3U-32MT/ESS PDF.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module
FX3U-32MT/ESS
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation FX3U-32MT/ESS PDF.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard FX3U-32MT/ESS PDF.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017). Voltage input: DC-10~10V.
Current input: DC0~20mA.
Channel number: 4 channel analog output.
Applicable PLC:FX1N, FX2N, FX3U, FX2NC (to FX2NC-CNV-IF).
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V).
Resolution of 11 bit binary + symbol 1 (voltage), 10 bit binary (current) high precision analog output module.
Voltage output and current output of 4 channels can be carried out.
Can be specified for each channel voltage or current output. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 160kw.
SLD converter rated current: 361A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
The motor efficiency is not changed in the previous optimal excitation control,
At the same time, the newly developed advanced optimal excitation control can obtain larger torque at startup.
No need to adjust the parameters (plus deceleration time or torque, etc.), in a short time to speed up to a certain speed,
Can be carried out to maximize the efficiency of energy-saving drive motor.
The automatic tuning function of the loop constant of the motor is not consistent with the constant of the motor, the motor of other manufacturers, and the length of wiring is too long,
Optimum operating characteristic drive mmotor FX3U-32MT/ESS datasheet.
In the state of the sensor can not only drive the high efficiency and energy saving motor and PM motor (MM-EFS), but also can drive other companies induction motor and PM motor (permanent magnet synchronous motor).
Othher manufacturers of induction motors, can also be automatically tuned to achieve the best excitation control, thus expanding the use of energy saving FX3U-32MT/ESS datasheet.