Input and output points: 14 points.
Power supply: DC24V.
Input points: 8 points.
Output points: 6 points.
Output form: relay output.
Power consumption: 6.5W.
Weight: 0.22KG.
Outline dimension: 60x90x49mm.
Built in CPU, power supply, input and output.
Keep FX1S compact body, while adding more features FX5-16EYR/ES PDF.
Special adaptor and function expansion board can be installed and used FX3 series
FX5-16EYR/ES
High speed operation.
Basic instructions: 0.21 s/ instruction
Application instruction: 0.5 s/ instruction
Large capacity memory.
Built in program memory 4000 steps.
No battery.
Auxiliary relay: 1536 points.
Timer: 138 points.
Counter: 67.
Data register: 3000.
A new application model.
FX3SA is a basic model on the basis of the basic performance of the FX1S increased the expansion of the new models FX5-16EYR/ES PDF.
FX3SA is suitable for all kinds of fields, such as analog quantity, Ethernet, MODBUS function, small scale equipment and so on.
Basic models suitable for small scale control.
Compact but powerful,
At the same time, the analog quantity and the communication function and so on. MITSUBISHI inverter series: FR-F840 FX5-16EYR/ES PDF.
Voltage level: three phase 400V.
Power: 11kw.
SLD converter rated current: 25.0A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption.
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control. Can be used as a screw relay terminal.Power: 15kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR--A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity FX5-16EYR/ES datasheet.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motorr power used to select the DC reactor FX5-16EYR/ES datasheet.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.)