"IE Field CC-Link master / local station
Transmission speed: 1Gbps.
Remote input / output: 16384 points.
Remote register: 8192 words.
Can be applied to the serial number of the top 5 for the "13012" and after the CPU module.
Simply set the parameters, you can easily start the network.
Simply use the Works2 GX, set the network parameters in the 1 master station, you can easily connect all the slave stations L6EXB-CM PDF
L6EXB-CM
Also, when you need to change the system, you only need to change the parameters.
High degree of freedom network
Build star, linear, star and linear mixed model, and ring network,
Therefore, can freely set the scene equipment.
When you use HUB, you just need to connect the cable to the free port to build the network easily,
Additional equipment and re layout of the corresponding is also more simple L6EXB-CM PDF. "Output points: 64 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 64 points (I/O distribution: output 64 points).
External wiring connection: 40 pin connector two L6EXB-CM PDF.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol. Number of input channels: 4ch.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 40 s/2ch.
Resolution: 1/32000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth continuouss analog output L6EXB-CM datasheet.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period L6EXB-CM datasheet.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.