CC-Link IE field network CC-Link bridge module.
Can support Ver.1 CC-Link remote I/O station and remote device station connected to the IE CC-Link field network.
CC-Link parameters can be set by a simple switch operation.
According to the original station number order, will be allocated to the bridge module of link equipment as CC-Link remote station equipment distribution link NZ2GF-CCB PDF.
The IE CC-Link field network and the CC-Link loop transmission are independent of each other
NZ2GF-CCB
The function module of MELSOFT Library (FB), the cache access bridge module,
To confirm and diagnose the running state of CC-Link. SD memory card 2GB.
Can be used on the Q24DHCPCPU-V.
Can be used on the Q24DHCPCPU-LS.
Can be used on the QnUDVCPU NZ2GF-CCB PDF. Type: 18 point terminal.
Input / output form: analog voltage and current input.
Number of channels: 4 channels.
No need to extend or change the network wiring to increase the number of analog points.
The conversion speed of the analog input module can be selected from 100 mu s/ channel, 400 mu s/ channel and 1ms/ channel. (switching speed switching function)
The conversion speed of the analog output module is 100 mu s/ channel NZ2GF-CCB PDF.
Can be connected to the analog input / output module (NZ2GF2BN-60AD4, NZ2GF2BN-60DA4) after the use of.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station. SD memory card 16GB.
Can be used on the Q24DHCPCPU-V.
Can be used on the Q24DHCPCPU-LS.
Can be used on the QnUDVCPU.Type: 18 point terminal.
Output points: 16 points.
Rated voltage: DC12/24V (0.5A).
Output type: leakage type.
External connection: 1 wire.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be conneected to the expansion module, more convenient to expand the input and output points NZ2GF-CCB datasheet.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Mastter) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station NZ2GF-CCB datasheet.