"1ch RS-232.
1ch RS-422/485.
QJ71C24N (-R2) through the RS-232 serial communication,
Programming and monitoring of programmable controllers using programming tools.
QJ71C24N (-R2) with the function of the modem corresponding to the public telephone line,
Can be used to initialize the modem, and the connection of the object device processing,
Communication with a remote device, a programming tool, a modem, and a public telephone line Q26UDHCPU PDF
Q26UDHCPU
Using remote password,
Can be prevented by QJ71C24N (-R2) function of the modem Q series programmable controller for illegal access.
Serial communication module capable of collecting and changing data of programmable controller, monitoring and managing, measuring data collection and so on Q26UDHCPU PDF.
Can achieve the highest speed of 230.4kbps, the maximum of 960 words (MC protocol communications) of the high speed and large capacity communications.
Can use MC protocol, through the external devices (PC, monitors, etc.) to implement the data read / write programmable controller.
By selecting a non sequential protocol and use sequential program for communication control, the programmable controller and the external device (barcode reader and measurement equipment),
Communication with local protocols using external devices Q26UDHCPU PDF. "PCI bus.
Support Japanese, English OS.
SI/QSI/H-PCF/ broadband H-PCF cable.
Dual loop controller network (control station / common station).
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation.
Province distribution network module in cabinet and device Q26UDHCPU datasheet.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Linkk/LT from the station does not need any parameter settings Q26UDHCPU datasheet.
Only need to set up the transmission speed in the master module, you can use the remote I/O.