Input: 2 channels.
200/100/10kpps.
Counter input signal: DC5/12/24V.
External input: DC5/12/24V.
Uniform output: Transistor (drain type).
DC12/24V.
0.1A/ point.
0.4A/ common end.
40 pin connector.
Support high resolution devices. Pulse input and high speed counter module product group satisfying high speed and high precision control application QD62D PDF.
High speed counter module for counting high-speed pulse train
QD62D
Can be used in combination with the external encoder for positioning and other control.
The maximum count rate can be switched, and the low frequency pulse is counted from the high speed pulse to the rising edge / falling edge.
Each 1 channel is equipped with 2 points of external uniform output QD62D PDF.
Can be selected according to the use of "consistent output function", "continuous comparison function", to achieve high-speed control of external equipment. (QD64D2)
Provides a variety of functions, such as the same output test function (using a continuous comparison function), the default function, the latch counter function,
In order to meet the needs of various applications. (QD64D2)
The maximum count rate of the input pulse can be up to 8Mpps (differential input, 2 phase, 4 double frequency) QD62D PDF.
Can be in the semiconductor, liquid crystal manufacturing and other high position accuracy requirements of the equipment,
Perform accurate position tracking using high resolution encoders. (QD65PD2)Empty cover plate for I/O groove.Cable length 3 meters.
Extended substrate for connection.SRAM memory card, capacity: 2M bytes.
Size: 45*42.8*3.3mm
Weight: 15g.
Support SD memory card.
High speed universal QCPU support SD memory card,
In order to be able to have a memory card port between SD and PC to easily realize data exchange.
In addition, the SD memory card and the extended SRAM card can be used simultaneously.
Therefore, the extension of the file register using the extended SRAM card,
SD memory card can be used at the same time to carry out the data file record, a large number of annotation data storage, through the memory card to guide operation.
Better user experience data recording function.
Easy to record, no need to program.
Simply through the special configuration tool wizard to easily complete the settings,
The collected data can be saved in CSV format to SD storage card.
Can be effectively used to save the CSV file to facilitate the creation of a variety of reference materials,
Including daily reports, generate reports aand general reports QD62D datasheet.
These data can be applied to the data analysis, tracing, etc..
To record the change of control data without missing.
Data can be collected in a time interval or in a millisecond time interval,
To record the changge of the specified control data without any omission QD62D datasheet.
Therefore, in the event of failure, can quickly determine the cause, the precise action analysis.