Differential input, transistor (drain type) output.
Channel number: 2CH.
External wiring connection mode: 40 pin connector
Count input signal: there
Single phase input (single frequency / double frequency)
Dual phase input (single frequency and double frequency /4)
CW/CCW input: there
The signal level (phi A, Phi B): EIA standard RS-422-A differential line driver level RX40PC6H PDF.
PWM output function can be output through the highest frequency of 200kHz, minimum ON 100ns width of the PWM waveform of any duty cycle
RX40PC6H
In addition, the output cycle and duty cycle can be changed when the output PWM,
The use of the most suitable for the use of continuous PWM signal flow control. "Axis of control: 32.
Program language: motion SFC, special instruction RX40PC6H PDF.
Servo program capacity: 32K.
Location points: 6400 (indirect).
Servo amplifier connection mode: SSCNET III /H (2 system).
Suitable for a variety of purposes.
Winding material, such as film, can be put down by fixed tension.
Speed control using advanced synchronous control,
To keep the entire production line in sync.
Workpiece position can be obtained directly from the visual system,
High speed motion control to change the position of the target in the process of operation, reduce the positioning time RX40PC6H PDF.
Advanced synchronous control and speed / torque control,
High speed and high precision synchronous control of various printing modules.
Motion SFC program.
Motion CPU module through "Function Chart Sequential", in the form of flow chart description of motion control program.
The program can be used to describe the motion CPU module of the SFC module, which is suitable for event processing,
Using motion CPU module to control a series of movements of equipment, improve the response of the event. "Analog input channel number: 4CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C: plus or minus 0.3%.
Temperature coefficient.
Common
Conversion speed: 80 s/CH.
Channel to channel insulation.
Absolute maximum input: positive and negative 15V, 30mA.
External wiring connection mode: 18 point screw terminal.
Voltage input
The analog input voltage: DC - 10 - 10V.
Digital output value: 32000 ~ 32000.
Current input
Analog input current: DC0 ~ 20mA.
Digital output value: 0 ~ 32000.
16 bit high resolution (1/32000).
No program can perform scaling and conversion operations.
The most suitable for the requirements of speed and accuracy of the detection equipment.
Easy to filter high frequency interference.
Execute event driven programs via alarm output.
Through the engineering software, the output of arbitrary analog waveform data.
Channel insulation.
Similar to the input and output modules, analog quantity module is the interface between the sensor and the programmable controlller RX40PC6H datasheet.
The difference between the input and output modules is that it is dealing with analog voltage and current signals rather than ON/OFF signals.
The analog module MELSEC iQ-R series is equipped with high-speed conversion (80 s/CCH), high resolution (1/32000), channel insulation, abnormal signal detection and other convenient features,
Can achieve high precision analog control RX40PC6H datasheet.