Analog input channel number: 8CH.
Cold end compensation precision.
Available thermocouple: -.
Available temperature resistance: Pt100, JPt100, Ni100, Pt50.
Resolution: 0.1.
Conversion speed: 10ms/CH.
Insulation between channels: isolation transformer insulation.
Disconnection detection: there.
External wiring connection mode: 40 pin connector RY40PT5B PDF.
output
The temperature measurement value (16 bit''signed binary): 2000 ~ 8500
RY40PT5B
Zoom value (16 bit with symbol binary).
No program can perform conversion operations, scaling
Easy to use parameters to set the conversion operation and scaling, no need to create a dedicated program.
Therefore, it is helpful to reduce the development cost of the program and to reduce the program capacity RY40PT5B PDF.
High speed data sampling is not affected by the scan time.
The analog input module has the function of recording, which can be used to collect the analog quantity input data in the industrial application.
Can continuously collect data in a set period, each channel can store up to 10000 points of the recorded data.
In addition, the state of the state of any time and data in the program can be changed as a trigger,
To stop collecting data RY40PT5B PDF. The analog quantity input data can be stored and maintained before and after the trigger state through the function,
Easy to determine the occurrence of the phenomenon and the collection of test data. Such as motor testing equipment used in this function.
Control instructions from a programmable controller to a transducer and a power meter transmission test mode,
At the same time, the test data of the test motor is collected at the same time. Operation control mode: stored procedure repeated operation.
Built in IE CC-Link.
Input / output points: 4096 points.
Program capacity: 160K step.
Easy to collect and display the value of soft component.
With simple parameter setting, the value of the soft component can be collected as the record data,
Save to the SD memory card, or through the USB/ Ethernet for real-time monitoring.
Using the data collected by the reecording function to support the Unicode text format,
Can be easily recognized by LogViewer GX and spreadsheet software RY40PT5B datasheet.
In addition, LogViewer GX can also be used to monitor the function of real time,
Easily confirm the time of ssmall changes in the object''s soft components RY40PT5B datasheet.
These features can be traced back to improve and set up a fault when the commissioning of a great help.