Name: External Connector.
Model: C500-CE404.
Specifications: Solder terminal; 40p and a Connector Cover (Horizontal-type).Specifications: Two RS-422A/485 ports.Model: CPM2A-60CDT1-D. Power supply: DC power supply.
Output type: Transistor sourcing.
Inputs points: 36 points.
Outputs points: 24 points CJ1W-EIP21 PDF. Model : CVM1-MP201-V2.
Position Control Unit (NC222) for.C1000H-CP CPU 62 k words 1024 pts C1000H-CPU01-V1
CJ1W-EIP21Model: C200HS-INT01.
Rated Input Voltage: 12 to 24 VDC +10%/–15%.
Input Impedance: 2 K.
Input Current: 10 mA typical (24 VDC).
ON Voltage: 10.2 VDC min.
OFF Voltage: 3.0 VDC max.
ON Response Time: 0.2 ms max.
OFF Response Time: 0.5 ms max.
No. of Circuits: Name: Space Module.
Model: C200H-BAT09 CJ1W-EIP21 PDF.
Description: Replacement for memoryUnit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 32 inputs/outputs;
External connection, Removable terminal block.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmits 16 points of I/O signals per,
word with a pair of cables.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal without,
any need to worry about communications CJ1W-EIP21 PDF.
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator.
Model: CPM2A-30CDR-D. Power supply: DC power supply.
Output type: Relay.
Inputs points: 18 points.
Outputs points: 12 points.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 4 to 20 mA, 1 to 5 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacee compared,
with previous systems CJ1W-EIP21 datasheet.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ1W-EIP21 datasheet.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.