Name: CompoBus/S Master Module.
Model: C200HW-SRM21-V1.
Communications protocol: Dedicated CompoBus/S protocol.
CompoBus/S Master Unit
High-speed ON/OFF Bus Saving Wiring Effort and Manufacturing Steps in Factories.Model : C500-PS221.
100 to 120 VAC or 200 to 240 VAC (selectable).
Output ratings: 7 A, 5VDC CP1E-E20DR-A PDF. Model: CPM2C-20EDR. Units with 20 I/O points.
1 I/O terminal block.
Inputs: 12 inputs
CP1E-E20DR-A
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: relay.Unit type: CS1 Basic I/O Units.
Product name: DC Input Unit.
Specifications: 24 VDC, 7 mA,
64 inputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3,YES, @@2, YES;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,@@3,YES,
@@2, YES; CS1 Long distance Expansion Rack,
Yes; SYSMAC BUS Slave Rack, No CP1E-E20DR-A PDF.
Words required: (I/O bits: CIO 0000 to CIO 0319), 4 words.
Current consumption: 5V system, 0.15A;
26 V system, --.
Standards: UC1, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Model: CPM2C-20CDT1C-D. CPU Unit: Units with 20 I/O points.
2 Fujitsu connectors CP1E-E20DR-A PDF.
Inputs: 12 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.
Internal clock: --.Unit type: CS1 Special analog I/O Units.
Product name: Analog Output Units.
Specifications: I/O points, 4 outputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/4000 ;
Conversion speed, 1 s/point.
Externa connection, Removable erminal block.
Current consumption: 5V, 0.13A; 26V, 0.18A.
Standards: UC1, N, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals. Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 8 inputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can bbe reduced CP1E-E20DR-A datasheet.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CP1E-E20DR-A datasheet.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.