LK166
Home >> Download >> OMRON >> Catalog Download >> OMRON CP1E-N30DT-A datasheet PDF

OMRON CP1E-N30DT-A datasheet PDF

Brand: OMRON
Product model: CP1E-N30DT-A
Name: CP1E CPU Units
Sort: PDF datasheet
File language: English
File size: 3.99MB
Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 8 outputs;
Signal range selection:
Set separately for each output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V;
1/4,000 (Settable to 1/8,000) *2.
Conversion period: 1 ms/point,
(Settable to 250 μs/point)*2 CP1E-N30DT-A PDF.
Accuracy at ambient temperature of 25°C:
±0.3% of F CP1E-N30DT-AS.
External connection: Removable terminal block.
External power supply: 24 VDC +10% -15%, 140mA max.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.14A; 24V, 0.14*3.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data CP1E-N30DT-A PDF.
Analog Output Units for converting binary ,
data into analog output signals. Product name: CS1 CPU Backplane.
Specifications: For CS-series,
Unit only Note: C200H series,
Units cannot be mounted; 8 slots.
Appli cable CPU Unit: CS1 CPU Unit.
Basic I/O Units: CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, No;
C200H Group-2 High density I/O Unit, No CP1E-N30DT-A PDF.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, No.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.11A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. 100 to 120/200 to 240 VAC (switchable), Wired.Name: Two-tier Screw Terminal Block.
Specifications: Inputs; 8 inputs; PNP.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can bbe reduced CP1E-N30DT-A datasheet.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CP1E-N30DT-A datasheet.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.
Related products
OMRON
CP1E CPU Units
CP1E-N30DT1-D
OMRON CP1E CPU Units CP1E-N30DT1-D
Product name: N-type CPU Units with 30 I/O
OMRON
CP1E CPU Units
CP1E-N60DR-D
OMRON CP1E CPU Units CP1E-N60DR-D
Product name: N-type CPU Units with 60 I/O
OMRON
CP1E CPU Units
CP1E-N40SDT-D
OMRON CP1E CPU Units CP1E-N40SDT-D
Product name: NS1- type CPU Units with 40 I
OMRON
CP1E CPU Units
CP1E-N20DT1-D
OMRON CP1E CPU Units CP1E-N20DT1-D
Product name: N-type CPU Units with 20 I/O