Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: B, E, J, K, L, N, R, S,
T, U, WRe5-26, PLII, ±100 mV.
Conversion speed: 20 ms/4 inputs,
10 ms/2 inputs.
Externa connection: Removable erminal block CP1E-N40DT1-A PDF.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0
CP1E-N40DT1-A12A; 26V, 0.08A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value CP1E-N40DT1-A PDF.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CP1E-N40DT1-A PDF.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools. Name: Repeater Unit.
Specifications: A sub-trunk line can be,
connected downstream,
(for trunk-branch line configuration),
or further branching is enabled downstream,
(for configurations with no wiring restrictions),
in the same way as for a Master Unit.
A Repeater Unit can be used to branch,
the trunk line and increase the,
number of connected Units,
as well as to extend the length of the,
communications line.
Standards: CE, U, U1, L, N.
Simple and Intelligent Bit Slaves,
with Industry-standard e-CON connectors.
Slave Units capable of 2-point bit-level distribution.
The I/O power supply is supplied from tthe communications,
power in the previously connected flat cable, and has a,
short-circuit detection function for protection CP1E-N40DT1-A datasheet.
Industry-standard e-CON connectors.
Short-circuit protection safeguards the network,
from I/O short circuits CP1E-N40DT1-A datasheet.
Simple communications connections,
with flat cable and connectors.
Bit-level distribution to support,
essentially any application.