Model : CVM1D-PA212.
12A.
Attach two things in the same format in each base Please you.CPU Unit: CP1L-EM CPU Units with 30 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Relay output;
Inputs, 18; Output, 12 CP1E-N60S1DT1-D PDF.
Standards: CE
CP1E-N60S1DT1-D
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Name: SYSMAC LINK Module CP1E-N60S1DT1-D PDF.
Model: C200HW-SLK13.
Communications method: N: N token bus.
Transmission method: Manchester code, base band.
Transmission path: Daisy chain.
Weight: 500g max.Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications nits.
Specifications:Communications Interface,
1 RS-232C port and 1 RS-422A/485 port;
Communications functions,
The following functions can be,
selected for each port:
Protocol macro Host Link,
NT Links (1:N mode)Serial Gateway,
No-protocol Modbus-RTU Slave CP1E-N60S1DT1-D PDF.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.38A; 24V,--.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol. Power supply: DC power supply.
Output method: Transistor output source type.
Inputs points: 18 points.
Outputs points: 12 points.Required for Analog Input and Output Units: For two Analog Units.Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 2 loops,
heater burnout detection function;
Temperature sensor inputs: Thermocouple,
input (R, S, K, J, T, B, L);
Control outputs:: Open collector,
PNP outputs (pulses) CP1E-N60S1DT1-D datasheet.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output CP1E-N60S1DT1-D datasheet.