Specification: Platinum resistance thermometer input (Pt100, JPt100),
heater burnout alarm,
manual operation,
ON/OFF or advanced PID control,
transistor (NPN) output, 2 loops.One Ethernet Option Board can be mounted in either option board slot 1 or 2.
Note: Cannot be used for the CP1L-L10.CV500-MC Special I/O Unit Motion Control Servo Control 4 axis CV500-MC421 CP1L Series PDF. Power supply: DC power supply
CP1L Series
Output method: Relay output.
Inputs points: 6 points.
Outputs points: 4 points.Output type: Transistor sinking.
Inputs points: 12 points.
Outputs points: 8 points.Model: C200H-DA003.
Input points: 8.
Voltage input: 1 to 5V or 10 to 10 V or –10 to 10 V.Specifications: With clock (see below).C500-ID I/O Unit Interrupt Input Module 8 pts C500-ID216(3G2A5-ID216) CP1L Series PDF.
DC12-24V 13mA.Name: I/O Control Unit.
Specifications: Applicable systems,
Duplex CPU, Dual I/O Expansion System only;
Duplexing, Supported;
Online Replacement, Supported;
Mounting Backplane, Expansion Backplane;
Connecting Cable, CS1W-CN@@3,
CS-series Connecting Cable.
Current consumption: 5V system, 0.20A;
26V system, -- CP1L Series PDF.
Standards: UC1, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. NO. OF I/O SLOTS: 5 SLOTSUnit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: B, E, J, K, N, R, S, T, ±80mV.
Conversion speed: 150 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CP1L Series datasheet.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1L Series datasheet.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.