Name: Compact Connectors.
Specifications: Outputs; 4 outputs; PNP.
Bit slave of smallest class in industry,
Innovation in wiring for any type of machinery.
Available in 2 types: 2-point Bit Slave Unit,
and 4-point Bit Slave Unit.
Compact size for installation in limited space.
Save space and wiring since bit slave can be,
installed near I/O devices CRT1-ID16-1 PDF.
Industry first bit slave connectable with round,
cables which can be easily purchased at a lower price
CRT1-ID16-1
Connectable with flat cables, too for easy wiring.
Cables are selectable depending on applications. Model: CPM2C-20C1DT1C-D. CPU Unit: Units with 20 I/O points.
2 Fujitsu connectors.
Inputs: 12 inputs.
Outputs: 8 outputs.
Input type: 24 VDC CRT1-ID16-1 PDF.
Output type: sourcing transistor.
Internal clock: Yes.Can be used for backing up programs or auto-booting.Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 2 loops,
heater burnout detection function;
Temperature sensor inputs: Platinum ,
resistance thermometer input(JPt100, Pt100);
Control outputs: Open collector,
NPN outputs (pulses) CRT1-ID16-1 PDF.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output. Model: CPM2A-60CDR-A. Power supply: AC power supply.
Output type: Relay.
Inputs points: 36 points.
Outputs points: 24 points.Applicable CPU Units: CQM1H-CPU51/61.
Connection location and number of Units: One Unit only.The Unit must be connected between the Power Supply Unit and the CPU Unit.
Dimensions: 25 × 110 × 107 mm (W × H × D).
Weight: 170 g max.Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 16 inputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CRT1-ID16-1 datasheet.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CRT1-ID16-1 datasheet.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.