Unit classification: CJ1 Special I/O Units.
Product name: Position Control Units,
(High Speed type).
Specifications; Control method/Control,
output interface: Pulse-train open-collector,
output with Pulse Counter Function;
Number of control axes : 2 axes.
No. of unit numbers allocated: 2 CS1W-OD261 PDF.
Current consumption: 5V, 0.27A; 24V, --.
Standards: UC1, CE.
Motion Control Capabilities with Unit,
Synchronization and Even Higher Speed
CS1W-OD261
Models are available with 2 or 4 axes,
and open-collector or line-driver outputs.
The CJ1W-NC214/NC414 have open-collector outputs,
and the CJ1W-NC234/NC434 have line-driver outputs.
Control 2 or 4 Axes High-speed, high-resolution,
position control is possible for servomotors ,
and pulse motors, and even linear motors,
and direct drive motors CS1W-OD261 PDF. 8 pts, No-voltage contact. NPN.Model: Unit version 1.2.
NJ system: CPU Rack;Expansion Rack,
Not supported.
CJ1 system: CJ1 system, Expansion Backplane,
8 Units (per CPU Unit).
CP1H system: CP1H PLC, 2 Units.
NSJ system: Controller NSJ, Not supported;
Expansion Backplane, 8 Units.
New Controller Link Units,
Now with 4,000 Send Words CS1W-OD261 PDF.
The Controller Link is an FA,
network that can send and receive,
large amounts of data easily,
and at high speed.
The Controller Link supports data,
links that enable sharing,
data between PLCs and computers,
and a message service that enables,
sending and receiving data whenever required.
Systems can be flexibly built by using Repeater,
Units to enable T-branches, long-distance wiring,
and converting part of the network to optical cable. Model: CPM2C-24EDT1. Units with 24 I/O points
2 Fujitsu connectors.
Inputs: 16 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.A memory card suitable for Phoenix PCM+3.2 and one of thefollowing Bus Connection Units is required. No PC card is provided with the Unit.Name: e-CON Connectors.
Specifications: Outputs; 32 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost cann be reduced CS1W-OD261 datasheet.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CS1W-OD261 datasheet.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.