Type: 1-Conduit (High pull-force type).
Contact configuration: Slow-action; 2NC.
Conduit opening/Connector: G1/2.
Multi-contact, Labor-saving,
Environment-friendly, Next,
generation Safety-door Switch.
Lineup includes three contact models with 2NC/1NO,
and 3NC contact forms and MBB models in addition,
to the previous contact forms 1NC/1NO, and 2NC D4B-4111N PDF.
M12-connector models are available, saving on,
labor and simplifying replacement
D4B-4111N
Standardized gold-clad contacts provide high,
contact reliability.
Applicable to both standard loads and microloads.
Variety of metallic heads available. Lock method: Mechanical lock.
Conduit size: PG13.5.
Voltage for solenoid: 24 VDC.
Without indicator 2NC+ 1NC (Slow-action) D4B-4111N PDF.
Release Protective Cover Locks Using.
Controller Signals or Pushbutton.
Switches after the Cutting Tool Stops.
Moving Due to Inertia.
A mechanical lock is applied automatically when the Operation.
Key is inserted. A high level of safety is achieved using a,
mechanism where the lock is only released when voltage is,
applied to the solenoid.
Conforms to EN (TÜV) standards corresponding to the CE marking D4B-4111N PDF.
Certified by UL, CSA and CCC standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened.
Direct opening mechanism that is EN-certified is indicated by,
on the Switch.
Auxiliary release key ensures easy maintenance and unlocks the,
door in the case of a power failure.
Tough aluminum die-cast body incorporating a switch box with,
degree of protection satisfying IP67, UL, and CSA TYPE6P, 13.
Equipped with a horizontal and vertical conduit opening.
Models incorporating easy-to-see indicators for monitoring and,
those using an adjustable Operation Key for a swinging door are available.
The mounting direction of the head can be changed,
to allow the Operation Key to be inserted from four directions. Specifications: Inputs;
PNP (- common);
16 points.
I//O connections: MIL connector(Connector with 10-cm cable) D4B-4111N datasheet.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Termminals D4B-4111N datasheet.
Used in combination with Interface,
Conversion Boards (e.g., D-Sub) to,
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H).