Name: Enclosed Switch
Sort: PDF datasheet
File language: English
File size: 1.51MB
Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Roller lever, high sensitivity.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4C-4424 PDF. )
Sealing characteristics that meet IEC IP67 degree of protection D4C-4424
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables D4C-4424 PDF.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release D4C-4424 PDF.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @.
Conduit size (See Note.): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key inserrtion point D4C-4424 datasheet.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4C-4424 datasheet.
The plastic material makes the Slide Key suitable,
for lightweight doors.
Related products
OMRON
Enclosed Switch
D4C-6331
OMRON Enclosed Switch D4C-6331
Ratings: 0.1 A at 30 VDC. Cale: VCTF oil-re
OMRON
Enclosed Switch
D4C-4501
OMRON Enclosed Switch D4C-4501
Ratings: Standard load 0.1 A at 125 VAC, 0.1
OMRON
Enclosed Switch
D4C-2432
OMRON Enclosed Switch D4C-2432
Ratings: Standard load 5 A at 125 VAC. Cal
OMRON
Enclosed Switch
D4C-1224
OMRON Enclosed Switch D4C-1224
Ratings: Standard load 5 A at 250 VAC, 4 A a