Actuator: Plunger.
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available D4E-1E20N PDF. )
M12-connector models are also available, saving on labor and,
simplifying replacement
D4E-1E20N
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Ratings: Standard load; 0.1 A at 125 VAC, 0 D4E-1E20N PDF. 1 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Sealed pin plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material D4E-1E20N PDF.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Actuator: One-way roller arm lever (horizontal).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 3NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 22NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC D4E-1E20N datasheet.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability D4E-1E20N datasheet.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC.