Drive lever: swing lever type.
Terminal specification: solder terminal.
The protection structure is in conformity with the JIS''s anti immersion type, IP67 IEC (except for the terminal part).
Can be used in the environment temperature -40 ~ +85.
Through the use of gold alloy bar, contact springs to achieve longevity and high contact reliability D4E-1F00N PDF. Actuator: Roller lever (Metal lever, resin roller)
D4E-1F00N
Cable length: 5 m.
Pull-outing direction of cable: Vertical.
Built-in switch: 2NC/2NO (slow-action).
Smallest Class of Safety Limit Switches the World.
The world''s smallest limit switch with a direct opening,
mechanism (four-contact construction model).
High-sensitivity safety limit switch D4E-1F00N PDF.
Built-in switches with two- or four-contact construction are available.
Degree of protection: IP67.
Conforms to EN115-1, EN81-1 and EN81-2.
(slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Type: 1-Conduit.
Contact configuration: Slow-action; 2NC/1NO.
Conduit opening/Connector: M20.
Multi-contact, Labor-saving,
Environment-friendly, Next,
generation Safety-door Switch D4E-1F00N PDF.
Lineup includes three contact models with 2NC/1NO,
and 3NC contact forms and MBB models in addition,
to the previous contact forms 1NC/1NO, and 2NC.
M12-connector models are available, saving on,
labor and simplifying replacement.
Standardized gold-clad contacts provide high,
contact reliability.
Applicable to both standard loads and microloads.
Variety of metallic heads available. Actuator: One-way roller arm lever (vertical).
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 22NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC D4E-1F00N datasheet.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability D4E-1F00N datasheet.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC.