Ratings: 1 A at 30 VDC.
LED indicator: With indicator.
Actuator: Roller plunger.
Many Models Including Roller Lever.
Switches are Only 16-mm Thick with Connector.
New center roller lever models that enable ganged mounting.
of up to 6 Switches.
Cable connectors for easy Switch replacement.
Triple-seal construction to provide IEC IP67 degree of protection D4NH-8CBC PDF.
Operation indicators available for easy monitoring,
(standard indicator is lit when Switch is not operating)
D4NH-8CBC
Approved by UL and CSA.
(Ask your OMRON representative for Information on approved models.) Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC (Slow-action) D4NH-8CBC PDF.
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads D4NH-8CBC PDF.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: Roller lever (Metal lever, resin roller).
Cable length: 3 m.
Pull-outing direction of cable: Vertical.
Built-in switch: 1NC/1NO (slow-action).
Smallest Class of Safety Limit Switches the World.
The world''s smallest limit switch with a direct opening,
mechanism (four-contact construction model).
High-sensitivity safety limit switch.
Built-in switches with two- or four-contact construction are available.
Degree of protection: IP67.
Conforms to EN115-1, EN81-1 and EN81-2.
(slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: Roller plunger.
Conduit openings: G1/2 (PF1/2).
2NC (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever. D4NH-8CBC datasheet.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMA 3, 4, 4X, 6P, and 13) D4NH-8CBC datasheet.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.