LK166
Home >> Download >> OMRON >> Catalog Download >> OMRON D4SL-N4TFG-N datasheet PDF

OMRON D4SL-N4TFG-N datasheet PDF

Brand: OMRON
Product model: D4SL-N4TFG-N
Name: Guard Lock Safety-door Switch/D4SL-N-mounting Slide Key
Sort: PDF datasheet
File language: English
File size: 6.12MB
Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Sealed crossroller plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4SL-N4TFG-N PDF. )
Sealing characteristics that meet IEC IP67 degree of protection D4SL-N4TFG-N
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables D4SL-N4TFG-N PDF.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 1-conduit; M12 connector D4SL-N4TFG-N PDF.
Built-in switch mechanism: 1NC/1NO (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC//1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC D4SL-N4TFG-N datasheet.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability D4SL-N4TFG-N datasheet.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC.