Classification: Exclusive Models.
Description: Bayonet spring for molding machines.
Temperature range (See note 3.): 0°C to 350°C.
Element type: K (CA) J (IC).
Conductor type: Grounded type.
Class: 2 (0.75).
Protective tubing material: SUS304.
Terminal type: Exposed lead wires.
Page: 21.
A Wide Variety of High-precision E2A-M12LN08-M1-B1 PDF.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work
E2A-M12LN08-M1-B1
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E2A-M12LN08-M1-B1 PDF. Type: plug - in.
Size: 48 x 96mm.
Control output: voltage output.
Auxiliary output: 2 points.
Communication: -.
Heater disconnection: -.
Event input: -.
Power supply voltage: AC/DC24V.
Using large font PV display (white), improve visibility.
Selection, setting and operation more simple and more group of input / output,
Functional performance is stronger, the function is more perfect and more extensive range of applications E2A-M12LN08-M1-B1 PDF.
E5EC-800 white LCD-PV display height is about 18mm,
The E5AC-800 white LCD-PV display height is about 25mm improved visibility.
The main body is short, the thickness is only 60mm.
50ms high speed sampling period.
A new type of proportional control allows you to control the valve. Size: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RRUN/STOP, alarm), interactive display PV/SV E2A-M12LN08-M1-B1 datasheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E2A-M12LN08-M1-B1 datasheet.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.