LK166
Home >> Download >> OMRON >> Catalog Download >> OMRON E2A-M18LS08-WP-C1 2M datasheet PDF

OMRON E2A-M18LS08-WP-C1 2M datasheet PDF

Brand: OMRON
Product model: E2A-M18LS08-WP-C1 2M
Name: Cylindrical Proximity Sensor
Sort: PDF datasheet
File language: English
File size: 0.54MB
Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: Transfer output using control output.
Communi cations: -- E2A-M18LS08-WP-C1 2M PDF.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- E2A-M18LS08-WP-C1 2M
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0 E2A-M18LS08-WP-C1 2M PDF. 5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter E2A-M18LS08-WP-C1 2M PDF.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. The main body: terminal type, temperature input type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further perrformance improvement E2A-M18LS08-WP-C1 2M datasheet.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E2A-M18LS08-WP-C1 2M datasheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Cylindrical Proximity Sensor
E2A-M18LS08-M1-B2
OMRON Cylindrical Proximity Sensor E2A-M18LS08-M1-B2
Size: M18, Shielded. Sensing distance: 8.0 m
OMRON
Cylindrical Proximity Sensor
E2A-M18LS08-WP-B1 2M
OMRON Cylindrical Proximity Sensor E2A-M18LS08-WP-B1 2M
Size: M18, Shielded. Sensing distance: 8.0 m
OMRON
Cylindrical Proximity Sensor
E2A-M18LS08-WP-C2 2M
OMRON Cylindrical Proximity Sensor E2A-M18LS08-WP-C2 2M
Size: M18, Shielded. Sensing distance: 8.0 m
OMRON
Cylindrical Proximity Sensor
E2A-M18LS08-M1-B1
OMRON Cylindrical Proximity Sensor E2A-M18LS08-M1-B1
Size: M18, Shielded. Sensing distance: 8.0 m