Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent:
Detection for single-phase heaters.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: -- E2B-M12KN05-WZ-B2 2M PDF.
Previous model: Thermocouple input, --;
Resistance thermometer input, --
E2B-M12KN05-WZ-B2 2M
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0 E2B-M12KN05-WZ-B2 2M PDF. 5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter E2B-M12KN05-WZ-B2 2M PDF.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Fitting materials: Stainless steel (SUS304).
Count: 1.
Accessories: Description, Holder (upper) Holder,
(lower) Pipe Bolts M4 × 12 with Hexagonal holes,
Bolts M4 × 30 with hexagonal holes,
Phillips screws M3 × 12 (with spring and plain washers),
Spring washer M4 Plain washer M4 Nuts M4;
Material, Heat-resistant ABS resin, 66 nylon,
Stainless steel (SUS304), Iron, nickel plating,
Iron, nickel plating, Stainless steel (SUS304),
Iron, nickel plating, Iron, nickel plating,
Iron, nickel plating; Count, 1, 1, 1, 2, 1, 2, 1, 1, 3.
Applicable sensor (mounting pitch on sensor side): E3Z (25.4) E39-R1/E39-R3.
Page: Dimensions, 9. Name: HFU with Programless Communications *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sinking).
Functions: burnout Heater alarm, None; Event inputs, 4.
Communications functions: Port C: RS-422,
From End Unit: Port A: RS-485.
Input type: No input.
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi-cchannel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise E2B-M12KN05-WZ-B2 2M datasheet.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculaate the PID constants with the step,
response method E2B-M12KN05-WZ-B2 2M datasheet.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.