E3F3-D87M detection method: diffuse reflection type,
Lead extraction: CN M12,
Type: metal appearance; PNP output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologySize: M12 (Brass); Single; Unshielded E2B-M12KN05-WZ-B2 2M PDF.
Sensing distance: 20 mm.
Connecting method (See note 1
E2B-M12KN05-WZ-B2 2M): M12 Connector.
Body length: Short.
Output configuration: PNP.
Operation mode NC.
A new generation in global applications. Appearance: Shielded, M12.
Sensing distance: 4 mm.
Output configuration: DC 2-wire (no polarity) (3)-(4) pin arrangement.
Operation mode: NO.
Spatter-resistant Fluororesin,
coated Proximity Sensor E2B-M12KN05-WZ-B2 2M PDF.
Superior spatter resistance.
Long Sensing-distance Models added for sensing,
distances up to 15 mm.
Pre-wired Smartclick Connector Models are also available. Sensing method: Through-beam type.
Sensing distance: 300 mm.
Output type: NPN output.
Output configuration: Dark-ON.
Cable length: 2 m.
Cable length from emitter to amplifier: 0.5 m.
Compact, Thin-profile.
Photomicrosensor with special amplifier E2B-M12KN05-WZ-B2 2M PDF.
Slim amplifier (50 × 7.5 × 12 mm) can be handled like a cable.
Provided with two operation indicators, enabling monitoring from the,
amplifier housing and sensor head.
Simple wiring with a 3-conductor cable.
Wide operating voltage range: 12 to 24 VDC. Control output: voltage output (SSR driver).
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cablle (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E2B-M12KN05-WZ-B2 2M datasheet.
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthe basic function is complete E2B-M12KN05-WZ-B2 2M datasheet.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).