E3Z-L61-S0SRW-E2 fine beam
Reflective typeAppearance: M18.
Sensing distance: 7 mm.
Connection method: M12 Connector Models.
Cable specifications: --.
Polarity: Yes.
Operation mode : NC.
Pin arrangement: 1: +V, 2: 0 V.
Applicable connector code: D.
Your Search for Proximity Sensors.
Starts with the World-leading E2E-C06S02-MC-B1 PDF.
Performance and Quality of the E2E.
Standard Sensors for detecting ferrous metals
E2E-C06S02-MC-B1
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC and sensing surface made of material that resists,
cutting oil E2E-C06S02-MC-B1 PDF.
Useful to help prevent disconnection.
Cable protector provided as a standard feature. Output mode: E3C-LS3R detection mode: qualified reflection type.
Detection distance: 30 positive and negative 3mm.
Purpose: small,
Small thin space probe;
Interference prevention function with close installationSize: M8, Non-shielded.
Sensing distance: 4.0 mm.
Connection: Pre-wired.
Body material: Stainless steel E2E-C06S02-MC-B1 PDF.
Thread length (overall length): 49 (62).
Output configuration: NPN.
Operation mode NO.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-232C.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E2E-C06S02-MC-B1 datasheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E2E-C06S02-MC-B1 datasheet.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.