E3JM-10S4T detection methods: the firing pattern,
Connection: terminal plate,
Detection range: 10m.
Output status: ON into the light; light shading ON; switch conversion type.
Function: timer,
Output: DC no contact.
2 types of cost reductionAppearance: M4.
Sensing distance: 2 mm.
Connecting method: Pre-wired Models (2 m) E2K-C20MC1 PDF.
Cable specifications: PVC (oil-resistant).
Operation mode: NC
E2K-C20MC1
Wire color /pin arrangement: Brown: +V, Black: Output, Blue: 0 V.
Model: PNP output.
Ultra small size, but surprisingly easy installation!
With the addition of M4, 5.4-dia., 6.5-dia. size, unshielded,
pre-wired connector model, and connector model, a total of,
108 model variations are available.
High-speed response frequency stably detects moving,
objects: 5 kHz max E2K-C20MC1 PDF.
Four indicator lamps for easier indicator positioning.
Special mounting brackets reduce time and efforts for,
installation.
Protective Stainless-steel Spiral Tube against wire,
breakage is available (M4, M5 only).
Models also available with standard cables that are 5 m long,
or with robot (bending-resistant) cables E2K-C20MC1 PDF. E32-DC200E type: standard type; standard,
Specialty: M3 screws (small),
Bending radius (mm): R10.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsName: HFU with Programless Communications *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sinking).
Functions: burnout Heater alarm, None; Event inputs, 4.
Communications functions: Port C: RS-485 or RS-232C selectable.
From End Unit: Port A: RS-485.
Input type: No input.
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the GG3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise E2K-C20MC1 datasheet.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calcullate the PID constants with the step,
response method E2K-C20MC1 datasheet.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.