Control output 1: Linear current output.
Control output 2: --.
Auxiliary output: Three.
Communications: --.
Heater burnout: --.
Event inputs: --.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance E2V-X2C2 2M PDF.
Handles More Applications
E2V-X2C2 2M
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other. Fitting materials: Stainless steel (SUS304) E2V-X2C2 2M PDF.
Count: 1 .
Accessories: Description, Slotted/Phillips screws M4 × 35,
Spring washer M4, Plain washer M4, Nuts M4;
Material, Stainless steel (SUS304), Stainless steel (SUS304),
Stainless steel (SUS304), Stainless steel (SUS304);
Count, 2; 2; 2; 2 .
Applicable sensor (mounting pitch on sensor side): E3G-MR19 (T), E3G-ML79 (T).
Page: Dimensions, 13. Easy Setting Using DIP Switch and Simple E2V-X2C2 2M PDF.
Functions in DIN 48 × 48 mm-size Temperature.
Controllers.
Easy setting using DIP switch.
Models with two alarms added to Series, ideal for temperature,
alarm applications.
Universal-input (thermocouple/platinum resistance thermometer),
models also available.
Clearly visible digital display with character height of 13.5 mm.
Models available with black in addition to white cases.
RoHS compliant. The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furtheer performance improvement E2V-X2C2 2M datasheet.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E2V-X2C2 2M datasheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.