Control output 1: Voltage output.
Control output 2: Relay output.
Auxiliary output: Two.
Communications: --.
Heater burnout: --.
Event inputs: --.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance E3JK-R4M2 PDF.
Handles More Applications
E3JK-R4M2
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other. New 96 x 96-mm and 48 x 96-mm Basic Temperature Controllers with,
Enhanced Functions and Performance E3JK-R4M2 PDF.
Improved Indication Accuracy and,
Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%).
Pt input: ±0.2% of PV (previous models: ±0.5%).
Analog input: ±0.2% FS (previous models: ±0.5%).
A PV/SV-status display function can be set to automatically,
alternate between displaying the status of the Temperature,
Controller (auto/manual, RUN/STOP, and alarms) and the PV or SV E3JK-R4M2 PDF.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Three-level display that simultaneously displays the PV, SV, and MV.
One-touch operation with PF Key that can be assigned to,
auto/manual, RUN/STOP, or other functions. Size: 48 x 48mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: 1 points.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a varietyy of applications E3JK-R4M2 datasheet.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermmo (sold separately) E3JK-R4M2 datasheet.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.