Size: 48 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points E3S-CD61 PDF.
Communication: RS-485.
Event input: 2 points.
Remote SP input: -
E3S-CD61
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports E3S-CD61 PDF.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications E3S-CD61 PDF.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Sensing method: Diffuse reflective.
Appearance: Vertical.
Connection method: Pre-wired .
Sensing distance: 12±2 mm.
Model: NPN Voltage output type .
Both Red-light Models and Green,
light Models to Detect a Wide Variety,
of Colors. Name: Basic Unit (temperature control) *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive) *2.
Control outputs 3 and 4: Transistor output: 2 points (sinking).
Auxiliary output: None.
Functions: burnout Heater alarm, 2 *3; Event inputs, 2 .
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to thee G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise E3S-CD61 datasheet.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calcullate the PID constants with the step,
response method E3S-CD61 datasheet.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.