Power supply voltage: 5 to 12 VDC.
Output configuration: Voltage output.
Resolution (pulses/rotation): 100, 200; 300, 360, 500; 600, 720, 800;
1,000, 1,024, 1,200; 1,500, 1,800, 2,000v; 2,048, 2,500, 3,600.
Connection method: Pre-wired (1 m) (See note.).
Rugged Rotary Encoder.
Incremental model E3X-DAC11-S 2M PDF.
External diameter of 50 mm.
Resolution of up to 3,600 ppr.
IP65 (improved oil-proof construction with sealedbearings)
E3X-DAC11-S 2M
Superior shaft loading performance.
(radial: 80 N, thrust: 50 N)Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling E3X-DAC11-S 2M PDF.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure E3X-DAC11-S 2M PDF.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 20 cm.
Lead wire type: Heat resistive.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Seensors E3X-DAC11-S 2M datasheet.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E3X-DAC11-S 2M datasheet.