High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC three wire / connector type.
Shape: non shield, M18.
Detection range: 10mm.
Output configuration: PNP.
Action mode: NC. Size: 1/8DIN 48 × 96 × 78 (W × H × D) E52-CA2GVF PDF.
Power supply voltage: 100 to 240 VAC.
Input type: Analog (Current, Voltage) Input Type
E52-CA2GVF
Control method: Valve Control.
Number of alarms: 2.
Communica- tions function: None.
Event input: 2 points.
A position proportional control model for the E5EZ-PRR series.
Depth of only 78 mm.
Various temperature inputs (thermocouple, platinum resistance thermometer,
infrared temperature sensor, voltage inputs) and analog inputs (current, voltage),
Makes use of high-visibility LCD, with three lines of 4-digit display,
for simplicity E52-CA2GVF PDF.
and clarity.
3 lines of display to observe PV/ SV/ MV (valve open percentage),
clearly displaying the state of control (operations).
Event input enables multi-SP selection and run/ stop function.
Alarm delay function.
Communications function.
Able to choose closed/floating control E52-CA2GVF PDF. In floating control,
position proportional control can be performed without a potentiometer,
Equipped with a manual output function (equipped with an automatic/manual key),
CE marking and UL/CSA certification. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / maanual, RUN/STOP, alarm), interactive display PV/SV E52-CA2GVF datasheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E52-CA2GVF datasheet.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.