1M E32-T51V type: environmental type; vacuum resistance,
Specialty: M4 screw heat: 200,
Shape / detection distance (mm): 1350; 1000; 680 (260),
Bending radius (mm): R30.
Standard test object (minimum test object) (mm) 1: 4 (0.1),
Fiber element for meeting diversified needsE32-T16WR type: special beam type; region detection,
Specialty: regional width 30mm,
Shape / detection distance (mm): 1700; 1300; 850 (340),
Bending radius (mm): R; R1 E52-CA6D-N PDF
E52-CA6D-N
Standard test object (minimum test object) (mm) 1: (0.3) 3,
Fiber element for meeting diversified needsSize: 48 x 24mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type (with terminal cover) E52-CA6D-N PDF.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc E52-CA6D-N PDF. .
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately). E3JK-R32 regression reflection type,
E3JK direct current mode: mode; ON,
Miniature amplifier built-in type photoelectric switchSize: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / maanual, RUN/STOP, alarm), interactive display PV/SV E52-CA6D-N datasheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E52-CA6D-N datasheet.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.