Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 3 points (common universal).
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater disconnection, SSR fault detection function: 1 points E52-P35AY D=6.4 NETU 1M PDF.
Communication: -.
Event input: 2 points.
Remote SP input: -
E52-P35AY D=6.4 NETU 1M
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications E52-P35AY D=6.4 NETU 1M PDF.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication E52-P35AY D=6.4 NETU 1M PDF.
Combined temperature control device through component communication. E3F3-R67M detection methods: Regression reflection type,
Lead extraction: CN M12,
Type: metal appearance; NPN output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologyPower supply voltage: 12 to 24 VDC.
Output configuration: Open-collector output (PNP).
Output code: Binary.
Resolution (divisions): 32, 40.
Connection method: Pre-wired Model (1 m).
Rugged Rotary Encoder.
Absolute model.
External diameter of 50 mm.
Resolution of up to 1,024 (10-bit).
IP65 (improved oil-proof protection with sealed bearings).
Optimum angle control possible in combination with PLC or,
Cam Positioner. Name: Temperature Controller (See note 1.).
Power supply: 24 VDC.
No. of control points: 2.
Control output: Voltage output (for SSRs).
Auxiliary output: Transistor output: 2 pts (sourcing).
Functions: Heater burnout alarm (See note 3.), Heating or heat/cool,
control is selectable (See note 4.)Event input: 1 point per Unit.
Communications functions: RS-485.
Input type (See note 5.): Thermocouple.
New DIN Track Mounting Temperature.
Controller.
Two channels of temperature control available despite width of,
only 22.5 mm.
The Temperature Controller itself can be replaced without,
changing terminal wiring E52-P35AY D=6.4 NETU 1M datasheet.
Use in combination with a compact Setting Display Unit to,
reduce communications programming requirements.
Front-panel LED indicators for easy operation monitoring.
Power supply and communicatiions wiring not required between,
Units when mounted side-by-side E52-P35AY D=6.4 NETU 1M datasheet.
CompoWay/F communications protocol supported.
UL, CSA, and CE Marking compliance.