Size: 96 x 96mm.
Control output 1: relay output (open).
Control output 2: relay output (off).
Auxiliary output: 2 points.
Communication mode: RS-485.
Heater disconnection: -.
Event input: 2.
Power supply voltage: AC100 ~ 240V.
New highlight LCD panel, font larger, display more clearly integrated low power design,
Longer life performance stability,
Perfect function of proportional valve control special (some models have no potentiometer input virtual opening function)
E5AC-PR-800 white LCDPV display height to reach 25mm, greatly improve the visibility E5CN-CQ2BL PDF
E5CN-CQ2BL
The main body is short, and the diameter is only 60mm.
50ms high speed sampling period. Size: 48 x 48mm.
Control output: voltage output (SSR driver) E5CN-CQ2BL PDF.
Auxiliary output: 2 points (common universal).
Power supply voltage: AC100 ~ 240V.
Terminal type: insert type.
Input category: full range multi input.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility E5CN-CQ2BL PDF.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) maakes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5CN-CQ2BL datasheet.
Through the infrared port can be carried out from the frront of the communication E5CN-CQ2BL datasheet.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.