Power supply voltage: 5 to 12 VDC.
Output configuration: Open-collector output (NPN output).
Output phases: Phases A .
Resolution (pulses/rotation): 10, 20, 60, 100, 200, 300, 360, 500.
Compact Encoder with External.
Diameter of 25 mm.
Incremental model.
External diameter of 25 mm.
Resolution of up to 500 ppr E5EC-TRX4DSM-080 PDF. Control output: linear current output.
Auxiliary output: 2 points
E5EC-TRX4DSM-080
Heating wire break, SSR fault detection function: -.
Event input: 1 points.
Communication: -.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type E5EC-TRX4DSM-080 PDF.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E5EC-TRX4DSM-080 PDF.
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm). Free change detection direction.
Small, can press the front, side (15 degrees) position change detection direction.
Type: small detection variable terminal plate / DC type.
Shape: non shield.
Detection range: 15mm.
Output status: NO/NC PNP (conversion). Size: 48 * 48mm, terminal type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event input points: -.
Transfer output: -.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the theermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5EC-TRX4DSM-080 datasheet.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E5EC-TRX4DSM-080 datasheet.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.