Brand: OMRON
Product model: E5EN-RQ3BT-N
Name: Foundation type temperature controller
Sort: PDF datasheet
File language: English
File size: 1.31MB
Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E5EN-RQ3BT-N PDF E5EN-RQ3BT-N
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type E5EN-RQ3BT-N PDF.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. E32-D21R type: standard type; soft (new standard),
Specialty: M3 screws (small),
Bending radius (mm): R; R1 E5EN-RQ3BT-N PDF.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsCase color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Teemperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5EN-RQ3BT-N datasheet.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5EN-RQ3BT-N datasheet.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Related products
OMRON
Foundation type temperature controller
E5EN-R3HBL-N
OMRON Foundation type temperature controller E5EN-R3HBL-N
Size: 48 x 96mm. Ontology: terminal type, ana
OMRON
Foundation type temperature controller
E5EN-R3HT-N
OMRON Foundation type temperature controller E5EN-R3HT-N
Size: 48 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5EN-QQ3BT-N
OMRON Foundation type temperature controller E5EN-QQ3BT-N
Size: 48 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5EN-R3HT-W-N
OMRON Foundation type temperature controller E5EN-R3HT-W-N
Size: 48 x 96mm. Ontology: terminal type, tem