Appearance: Shielded, M18.
Sensing distance: 7 mm.
Model: Operation mode, NO.
Proximity Sensor with a Long Screw Length.
Increased tightening strength. Cable protectors,
provided as a standard feature.
Increased indicator visibility.
A milled section for wrench grip on all models.Power supply voltage: 12 to 24 VDC E5EZ-C3ML PDF.
Output configuration: Open-collector output.
Detects the Rotary Encoder Direction
E5EZ-C3ML
Input phase difference signal from the Encoder to detect the,
direction of rotation.
High-speed response at 120 kHz.
Mounts to DIN Track. Thin design enables superb mounting efficiency.
Front-panel switch enables reversing phase Z logic.
Enables connecting either voltage outputs or open-collector outputs E5EZ-C3ML PDF. High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC three wire / connector type.
Shape: shield, M18.
Detection range: 5mm.
Output configuration: PNP.
Action mode: NO. Size: 1/16 DIN 48 × 48 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Analog (current/voltage) E5EZ-C3ML PDF.
Alarm output: 2.
option units Mounting: Yes.
Control output: Voltage output(for driving SSR).
Previous mode: None.
This Best-selling General-purpose,
48×48-mm Temperature Controller,
Is Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Easy setting with 11-segment displays.
Setting protection indicator informs operator when,
protection is enabled.
Manual output provided.
New protocol called Modbus is installed in the models,
with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: ES1B power supply.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furtther performance improvement E5EZ-C3ML datasheet.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E5EZ-C3ML datasheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.