Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-232C.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- EE-SX871R 2M PDF.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance
EE-SX871R 2M Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0 EE-SX871R 2M PDF. 5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors EE-SX871R 2M PDF.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Special for extrusion forming machine.
Control output 1: voltage output (for driving SSR).
Control output 2: relay output.
Auxiliary output: 2 points.
Power supply voltage: 100 ~ 240VAC.
Resistance to environmental performance of the industry leader.
Sulfide gas, dust, condensation of the corresponding.
Environment specific temperature controller.
Temperature control performance outstanding.
High contrast display screen.
Set simple, easy to operate. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furtherr performance improvement EE-SX871R 2M datasheet.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV EE-SX871R 2M datasheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.