Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Applicable load: 45 A, 200 to 480 VAC.
Compact, Slim-profile SSRs with Heat,
Sinks. Models with No Zero Cross for,
a Wide Range of Applications G2RV-SR700 AC200 PDF.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output currents
G2RV-SR700 AC200 (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification). Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow) G2RV-SR700 AC200 PDF.
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: DIN track mounting *2.
Applicable load: 45 A, 200 to 480 VAC.
Number of pole: 3.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents G2RV-SR700 AC200 PDF. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification). Type: input module.
Insulation: photo coupler.
Action indicator: there.
Logic supply voltage: DC4 ~ 32V.
Logic supply current: 25mA.
Input rated voltage: AC100 ~ 240V.
I/O solid state relay can be used for OMRON I/O type G7TC relay terminal.
Input and output composite input module, the output module is complete.
Can be used for I/O type P7TF terminal. Can also be mixed with the I/O type G7T relay.
Can check the working status of SSR through the action indicator.
Have access to UL, CSA standard certification of the series of products have also been series (-US type)Input capacity: 16 points.
Rated current (ON current):
0.5 A/output, 4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1.2 V max.
(0.5 ADC, between each output,
terminal and the G terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current con sumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 180 g max.
Expansion functions: Enabled.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansion unit per one I/O terminal unit G2RV-SR700 AC200 datasheet. )
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary sswitch and with tool software G2RV-SR700 AC200 datasheet.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance.