Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Screw mounting.
Applicable load: 15 A, 200 to 480 VAC.
Number of pole: 2.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase G32A-B AC200/240 PDF.
Heaters Reduced Installation Work.
with DIN Track Mounting
G32A-B AC200/240
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)) G32A-B AC200/240 PDF.
Conforms to UL, CSA, and EN standards (TÜV certification). Small 4 point output terminal relay with C contact relay.
Built in 4 G6B-2114P-US.
LED with action indication.
Diode built-in surge absorber.
Socket special, so the replacement of the relay is simple.
DIN guide rail installation, screw mounting common. Type: output module.
Insulation: photo coupler G32A-B AC200/240 PDF.
Action indicator: there.
Zero trigger function: No.
Applicable load of output: DC48 1A ~ 200V.
Input rated voltage: DC24V.
I/O solid state relay can be used for OMRON I/O type G7TC relay terminal.
Input and output composite input module, the output module is complete.
Can be used for I/O type P7TF terminal. Can also be mixed with the I/O type G7T relay.
Can check the working status of SSR through the action indicator.
Have access to UL, CSA standard certification of the series of products have also been series (-US type)Loose wire cable /G79-A_C.
L size: 5000mm.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Safety outputs: --.
Safety standstill detection output: 3.
Auxiliary output: 2.
Rated voltage: 24 VDC.
Terminal block type: Spring-cage terminals.
Sensor-less Monitoring of Standstill for,
Machines with Long Inertia.
Standsttill is monitored by the motor''s back electromotive force (BEMF) signal G32A-B AC200/240 datasheet.
Features a "Standard Configuration", allowing immediate use,
without sensitivity adjustment.
"User Configuration" also available for fine-tuning of sensitivity G32A-B AC200/240 datasheet.
Detailed LED indications enable easy fault diagnosis.
Safety Category 4 (EN954-1), PLe(ISO13849-1),
SIL 3 (IEC/EN 62061) certified.