Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Applicable load: 15 A, 100 to 240 VAC.
Compact, Slim-profile SSRs with Heat,
Sinks. Models with No Zero Cross for,
a Wide Range of Applications G3HD-X03S-VD DC4-24 PDF.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output currents
G3HD-X03S-VD DC4-24 (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification). Number of elements: 2.
Insulation method: Phototriac.
Rated supply voltage: 12 to 24 VDC.
Applicable motor: 0 G3HD-X03S-VD DC4-24 PDF. 75 kW (4.8 A), 200 to 220 VAC.
Solid State Contactors That Can Drive 3-phase Motors Frequently,
and Achieve Harmonized Protection with Thermal.
Overload Relays.
Certified for UL and CSA.
Mount with screws or to DIN tracks.
Compact monoblock construction (W: 80 × H: 100 × D: 100 mm).
with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator.
Two-element models added to series G3HD-X03S-VD DC4-24 PDF. Type: input module.
Insulation: photo coupler.
Action indicator: there.
Logic supply voltage: DC4 ~ 32V.
Logic supply current: 25mA.
Input rated voltage: DC5 ~ 24V.
I/O solid state relay can be used for OMRON I/O type G7TC relay terminal.
Input and output composite input module, the output module is complete.
Can be used for I/O type P7TF terminal. Can also be mixed with the I/O type G7T relay.
Can check the working status of SSR through the action indicator.
Have access to UL, CSA standard certification of the series of products have also been series (-US type)Number of phase: Single-phase.
Control terminal block: Terminal block with small slotted screws.
Type: Constant current.
Capacity: 20 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 ccommunications to set manipulated variables and,
monitor load current G3HD-X03S-VD DC4-24 datasheet.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control G3HD-X03S-VD DC4-24 datasheet.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.