Cable with connector (1 to 2) /G79-O_C-_, G79-I_C-_.
L size: A, 1000mm; B, 750mm.
Output use.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Name: Safety Controller.
Number of I/O: Safety inputs, 10; Test outputs, 4;
Safety outputs, Solid-state outputs: 4; Standard outputs, 4 G3J-211BL-2 AC100-240 PDF.
Unit version: Ver
G3J-211BL-2 AC100-2402.0.
Easy programming for complex safety control.
Stand-alone Safety Controller for small and mid-sized machinery.
Three types of CPU with different I/O size to suit the application.
Four types of Expansion I/O Units for hard-wired diagnosis or standard signals.
Clear diagnosis and monitoring via Ethernet or Serial connection G3J-211BL-2 AC100-240 PDF.
Various kinds of safety devices directly connectable like noncontact,
switches and safety mats.
Easy design, verification, standardization and reusage of,
safety control by unique programming software.
ISO 13849-1 (PLe/Category 4), IEC61508 (SIL3) certified. Terminal (wire connection): Push-In Plus Terminal.
Applicable output load: DC load.
Zero cross function: -- G3J-211BL-2 AC100-240 PDF.
Rated input voltage: AC 100V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Input capacity: 32 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: PNP.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the V terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 100 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 210 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided ffor,
each connector G3J-211BL-2 AC100-240 datasheet.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
swwitch and with tool software G3J-211BL-2 AC100-240 datasheet.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.