Classification: Relay with Auxiliary Contact Block.
Structure: 4 poles + 2 poles.
Contact configuration: Relay, DPST-NO/DPST-NC; Auxiliary Contact Block, DPST-NO.
Rated Voltage: 12, 24 VDC.
Compact Electromagnetic Contactors That.
Switch 40 A at 440 VAC.
One pole carries 40 A.
UL 508 and UL 840 NC contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations) G3J-211BL DC12-24 PDF.
EN 60947-4-1 NC contacts (AC1 40 A 440 VAC, 50/60 Hz, 80,000 operations)
G3J-211BL DC12-24
Ideal for supply power to industrial inverters, servo drivers, and other devices,
and switching power to motors and other equipment.
The maximum load capacity of 160 A when using 4-pole parallel connections.
EN 60947-4-1 certification for mirror contact mechanism obtained by combining,
the Relay with an Auxiliary Contact Block G3J-211BL DC12-24 PDF.
Conforms to European PV standard (VDE0126).
Approx. 30% less operation noise than a standard electromagnetic contactor.
(Approx. 100 dB reduced to approx. 70 dB.)
Approx. 50% the volume of a standard electromagnetic contactor,
to help downsize control panels.
According to OMRON investigation of IIEC-AC1 50 A specifications G3J-211BL DC12-24 PDF. Name: System Units; I/O Power Feed Unit.
Specifications: Use when the total current,
consumption of the I/O Power Supply exceeds 4 A,
or to make the I/O Power Supply a separate system.
Standards: CE, UC, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Insulation method: Phototriac coupler.
Zero cross function: Yes.
Indicators: Yes(See page 5).
Rated output load: 20 A, 100 to 240 VAC (resistive load: AC, Class1).
Refer to Safety Precautions for All Solid State Relays.
Detects failures in SSR used for heater,
temperature control and simultaneously,
outputs alarm signal. This SSR supports the,
safe design of heater control systems, and,
contributes to maintenance improvements by the user.
Main detection items:
SSSR short-circuits and SSR open-circuits,
Alarm output possible to NPN/PNP-input devices G3J-211BL DC12-24 datasheet.
The failure-detection function is built-in and power is supplied,
from the main circuit power supply making wiring simple.
Slim design (width: 22 G3J-211BL DC12-24 datasheet. 5 mm) incorporating a heat sink.
In addition to screw mounting, DIN track mounting is also possible.
Certified by EC, UL, and CSA.