LK166
Home >> Download >> OMRON >> Catalog Download >> OMRON G3NA-D210B AC100-240 datasheet PDF

OMRON G3NA-D210B AC100-240 datasheet PDF

Brand: OMRON
Product model: G3NA-D210B AC100-240
Name: Solid State Relays
Sort: PDF datasheet
File language: English
File size: 4.48MB
Name: Multi-channel Power Controller.
Number of control channels: 4.
Heater burnout detection: Supported.
Load power supply voltage: 100 to 240 VAC.
Optimum Cycle Control for High-precision.
Control with Low Noise.
Smaller than a Normal Power Controller.
Enables low-noise power control in combination with zero-cross G3NA-D210B AC100-240 PDF.
SSRs. (See note.).
One Controller can control up to 8 SSRs G3NA-D210B AC100-240
RS-485 communications to set manipulated variables and,
heater burnout detection. The Smart FB Library for the G3ZA,
can also be used.
CE Marking.
Main Upgraded Functions.
Soft-start function added for lamp heaters.
Three-phase optimum cycle control added for three-phase heaters.
Combining with special CT for150-A current detection G3NA-D210B AC100-240 PDF.
Note: The G3ZA must be used in combination with an SSR without the,
zero cross function when the soft-start function is used. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 20 A at 24 to 240 VAC(See note 2.).
Rated input voltage: 100 to 120 VAC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A G3NA-D210B AC100-240 PDF.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)). Complete line-up of compact units,
including OFF-delayed safety output models.
17.5 or 22.5 mm width to save mounting space.
Simple wiring using screw-less terminals.
Easy maintenance with status indicators.
One unit for various safety devices, from contact input to PNP input. Number of elements: 3.
Isolation method: Phototriac coupler.
Rated powersupply voltage: 12 to 24 VDC.
Input method: No-voltage input (open and short circuited input).
Applicable monitor capacity (AC3): 3.7 kW (17.4 A), 200 to 220 VAC.
Monitor output: DC switching output.
New Modelss with AC Power Supply Input and,
Monitor Output Equivalent to Non-contact,
SPST-NO Join the G3J-T Series,
Limiting the starting current saves energy G3NA-D210B AC100-240 datasheet.
Certified for UL and CSA.
Mounts with screws or to DIN Track.

Compact design with heat sinks (3 G3NA-D210B AC100-240 datasheet. 7-kW models: 100 × 100 ×130 mm (W × H × D)).
Built-in snubber circuit and thyristor.
Built-in operation indicator.
Related products
OMRON
Voltage and current panel meter
K3HB-XVD-CPAC11 AC100-240
OMRON Voltage and current panel meter K3HB-XVD-CPAC11 AC100-240
Input type: DC voltage input type. Output ty
OMRON
Solid State Relays
G3NA-D210B AC100-240
OMRON Solid State Relays G3NA-D210B AC100-240
Isolation: Photocoupler. Zero cross function
OMRON
Time interval table
K3HB-PNB-ABCD1 AC100-240
OMRON Time interval table K3HB-PNB-ABCD1 AC100-240
Input type: NPN/ voltage pulse input type. E