Insulation mode: three end two-way switch coupler.
Zero trigger function: No.
Action indicator: there.
Applicable load of output: AC5 240V ~ DC5 1.0A ~ 100V.
Input rated voltage: DC5V.
With the same shape of the power FET MOS G2R relay AC/DC dual, can achieve 1A load switching performance.
Can achieve AC240V or DC100V, 1A load switch G3PE-535B-3H DC12-24 PDF.
Output open circuit leakage current: 10 A
G3PE-535B-3H DC12-24
Input / output voltage resistance AC2500V.
Built in input resistance and over voltage absorbing circuit.
Can be carried out AC full wave rectifier load, half wave rectifier load switch.
Standard certification: No.
Insulation mode: three end two-way photoelectric switch.
Zero trigger function: No.
Action indicator: there G3PE-535B-3H DC12-24 PDF.
Applicable load of output: AC100 3A ~ 240V.
Input rated voltage: DC24V.
With the LY1, LY2 large power relay with the same shape of the G3H series, the new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with LY (1 pole, 2 pole type).
A model with an action indicator to check the status of the input G3PE-535B-3H DC12-24 PDF. (type N)Category: relay output.
Points: 8 points (1a * 8).
Common line processing on the connector side: NPN correspondence (+ public).
Rated voltage: DC24V.
Achieve control cabinet miniaturization / save time,
Relay terminal for 8 point output.
Small size of 68 * high 80 * 44mm. (vertical installation)
Total wiring of connector cable.
The common end can be easily connected with the independent contact and the short circuit piece.
The G70D-SOC08 and G70R-SOC08 are connected by a short circuit chip.
When the relay does not need the tool, the relay is convenient to replace the work.
With terminal cover to prevent electric shock.
With action indication LED.
Diode for internal coil surge absorption.
DIN guide rail installation, screw mounting common. Control terminal block: Screwless clamp terminal block.
Type: Standard.
Capacity: 60 A, 100 to 240 VAC.
Heater burnout detection: No.
Communications: No.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 coommunications to set manipulated variables and,
monitor load current G3PE-535B-3H DC12-24 datasheet.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control G3PE-535B-3H DC12-24 datasheet.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.