Main contact: 3PST-NO.
Auxiliary contact: None.
Number of input channels: 2 channels.
Rated voltage: 24 VDC.
Less Wiring Required with Safety Light.
Curtain.
Sensor connector allows direct connection to OMRON F3SJ.
Safety Light Curtains with PNP outputs.
Reduces wiring and prevents incorrect connection G3PH-2150B AC100-240 PDF.
Connection to emergency stop switch also supported.
Conforms to EN standards (TÜV approval)
G3PH-2150B AC100-240
DIN track mounting possible. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 20 A at 24 to 240 VAC(See note 2.).
Rated input voltage: 200 to 240 VAC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A G3PH-2150B AC100-240 PDF.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV G3PH-2150B AC100-240 PDF.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)). Slimmest OMRON plug-in SSR with maximum width 6.2 mm.
Long electrical life and high speed switching.
Large plug-in terminals for reliable connection.
G3RV-D (DC load) models can manage resistive loads of 100 µA to 3.0 A.
LED indicator for visible operation checking
Convenient quick electrical connections possible with G3RV push-in models and cross bar connectors.
Low power consumption for energy savings.
G3RV is cUL listed when correct relay is matched with the G3RV Socket.Input terminals: Compact slotted screw terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 35 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures G3PH-2150B AC100-240 datasheet.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) G3PH-2150B AC100-240 datasheet.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.