Safety outputs *1: Instantaneous, 2 (Semi conductors);
OFF-delayed*2, 2(Semiconductors).
Auxiliary outputs *3: 2 (Semi conductors).
Logical AND connection input: 1.
Logical AND connection output: 1.
Max. OFF delay time *4: 3.0 s.
Rated voltage: 24 VDC.
Terminal block type: Screw terminals.
Electronic Detection Mechanism for G3PW-A260EU-S PDF.
Better Stability in Non-contact Door.
Switch Operation
G3PW-A260EU-S Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 10 A 100 to 240 VAC.
Rated input voltage: 12 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations G3PW-A260EU-S PDF.
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation G3PW-A260EU-S PDF.
Built-in temperature fuse prevents internal burning due to,
triac or relay malfunctions.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays. Compact Terminal Relay with 4 Independent.
Outputs.
Equipped with four G6B Mini-relays that are compact, highly sen,
sitive, and highly resistant to dielectric surges, and that can switch,
5 amps of power.
Sealed plastic construction used for relays.
Easy wiring with separated input/output terminals.
Special P6B Mounting Socket used to facilitate maintenance,
(except for high-reliability models).
UL and CSA certification for standard models,
(except for high-reliability models).
VDE certification for G6B-4BND/47BND/48BND for 12/24 VDC.
DIN Track mounting, and screw mounting models are available. Control terminal block: Screwless clamp terminal block.
Type: Standard.
Capacity: 60 A, 100 to 240 VAC.
Heater burnout detection: No.
Communications: No.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RSS-485 communications to set manipulated variables and,
monitor load current G3PW-A260EU-S datasheet.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control G3PW-A260EU-S datasheet.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.